Application scenarios
Applicable to office areas, hotels, access gates, office buildings, schools, shopping malls, shops, communities, public services and management projects need to use facial access control places.
Product characteristics
1.Supporting night light compensation with photosensitive sensor cooperation;
2.Support serial port, Wigan 26, 34 output, output content support configuration;
3.Dynamic face detection and tracking recognition algorithm based on video stream is adopted.
4.Support devices to store 10,000 people's databases locally. (a) Cloud platform devices support storing 50,000 face photos (less than 4,000 KB), 1 million recognition records (0.45 KB), 20,000 live snapshots (b) LAN devices support storing 20,000 face photos (photos are calculated according to 1,000 KB) and 1 million recognition records (including the most). Nearly 10,000 live snapshots;
5.When the face database is 3000, the recognition accuracy of 1:N is 99.7%.
6.Recognition speed is fast. (a) Face tracking and detection takes about 20 ms. (b) Face feature extraction takes about 200 ms. (c) Face comparison takes about 0.2 Ms. (1000 people database, average recognition takes many times). 0.5 ms. (10000 people database, average recognition takes many times.)
7.Supporting stranger detection and configurable stranger rank;
8.Supporting on-site photo preservation in face recognition or stranger detection;
9.Support HTTP interface docking;
11.Supporting the deployment of public network and local area network;
12.Supporting screen display content configuration;
13.Support Distance Recognition Configuration
Product Specification Table
Cylindrical Face Recognition
Machine
Screen
|
Size
|
5 inch, 170 degree IPS LCD screen
|
Resolving
|
480*854
|
Camera
|
Resolving
|
200W
|
|
Type
|
RGB Camera
|
|
aperture
|
F2.4
|
|
Focal Lenght
|
6mm
|
|
White Balance
|
automatic
|
|
Widedynamics
|
Support
|
|
Vertical wide
|
|
|
Angel Horizontal
|
|
Core Parameters
|
Angel CPU
|
4 Nuclei,1.8GHz
|
Device Interface
|
Memory 2GB,Storage 8GB
|
Interface Function
|
Audio refrquency
|
1 chanel audio ouput(line out)
|
Video
|
HDMI2.0,Type-A255091
|
Serial Communication interface
|
One RS232 Interface
|
Relay Interface
|
1 Relay Interface
|
Reset Interface
|
Reset button on extension line
|
Net work Interface
|
A RJ45 10M/100M Adpative Ethernet Pot
|
Face Detection
|
Supporting detection and tracking of 5 people at the same time
|
1:N Face Recognition
|
The recognition accuracy is 99.7% under the condition that
|
the false recognition rate is three-tenths of ten thousand.
|
Stranger Detection
|
Support
|
Recognition Distance Configuration
|
Support
|
UI Interface Configuration
|
Support
|
Interface Congfiguration
|
Support
|
Deployment Mode
|
Support the use of public and local area networks
|
Coventional Paramenters
|
Protection Level
|
IP66,Certain Dust-Proof and Waterproof Functions
|
Power Supply
|
DC 12V (±10%)
|
Working temperature
|
Negative20,Positive 85
|
Working Humidity
|
10%~90 %
|
Power waste
|
10W MAX
|
Equipment dimensions
|
560.25*φ114mm(High * Diameter)
|
weight
|
5kg
|
Shape size (mm)

Installation instructions
A Appearance Part Instructions
The schematic diagram of the gate head is shown in the following figure.
Note: If the cable interface is different from the diagram, see the cable supplement on the next page.

Cable supplement
If there is a three-in-one small board in the head of the gate (supporting Wigan 26, 34), the cable interface is another style, as shown in the figure.

If there is a three-in-one small board in the head of the gate (supporting Wigan 26, 34), the cable interface is another style, as shown in the figure.
A Appearance Part Instructions
According to the requirement of the installation site, a hole with a diameter of 50mm is opened in the space position of the gate, generally in the middle or front side.
As shown in the figure,⊕ is the recommended opening position.

Note: The opening position should be based on the actual application scenario and gate type. 50cm is only the reference value.
②Unscrew the nut at the bottom of the gate head column, pull the cable out of the nut and gasket, and remove the nut and gasket, as shown in the figure.
Note: At this time do not connect the network cable, power cord, etc., to avoid installation trouble.
③Insert the gate head and cable from top to bottom into the opening of the gate, as shown in the figure.
④Under the gate, the cable and cable interface are passed through gaskets and nuts in turn, and the nuts are tightened to align the threads, as shown in the figure.
⑤Connect power supply, network cable, screen screen screen start.
⑥Hold the column with both hands and turn it gently to adjust the angle of the brake, as shown in the figure. According to the recognition interface, the brake head is adjusted to the appropriate recognition angle.
Access Control Installation
The gate head is shown in the figure, and the green is the access control interface NO and COM. For other wiring, see the instructions in the Appearance Section.
一、Magnetic door wiring
1.1 schematic diagram for installation of magnetic door system
1.2 Schematic wiring diagram of touch switch for magnetic door
1.3 Schematic wiring diagram of mechanical switch for magnetic door
二、Automatic induction door wiring
2.1 Installation sketch of automatic induction door system
2.2 Diagram of wiring of automatic door induction switch
三、Installation Notes, Installation Notes, Installation Notes
1、The cables inside the touch switch panel should be as far away from the central area on the back of the panel as possible.

2、In actual wiring, if the 12V power supply line of the main engine does not use "special power supply extension line" and the distance is long, which leads to the cable equivalent resistance too large, it is easy to appear abnormal phenomena such as terminal voltage insufficiency (< 11V), repeated restart of the main engine, crash and so on. The connection of voltage measurement is shown in the figure.
3、The equipment has its own power adapter as shown in the figure. The total length of the adapter is 1 meter. The power line is 40 cm (low voltage wire) and the power line is 40 cm (high voltage wire).

1)The extension of the power supply line (weak current part) should not exceed 2 meters, otherwise it will lead to insufficient voltage supply at the main terminal of the equipment, and abnormal phenomena such as repeated restart and crash will occur. If the power supply is far from the equipment, it can extend the power supply line (strong part).
2)If other adapters are used, such as 9V and 1A, insufficient voltage and low current will lead to repeated restart of the equipment.
3)The cables used should not be too thin (e.g. thin wire). It is recommended to connect multiple identical cables in parallel or to use copper-core-thickened cables to ensure voltage > 11V.
Note: If using wire, the extension wire will be positive with 4 strands of wire and negative
with 4 strands of wire.
4) If it is not clear how to extend, please contact the supplier to replace the "special power extension line".