iHM48-2T07-T4-EN Face Recognition Temperature Measurement Series
|
|||
Smart Function |
Face Recognition |
Live body detection |
Visible light + NIR binocular camera, accurate recognition. Live body detection and accurate recognition under various environments. Resist on the non-livings such as photos, videos and face models. |
Face comparison |
Built-in database, supports face capture and real-time comparison with the local data, and create a comparison log |
||
Recognition accuracy |
≥99.5% |
||
Recognition type |
1 : N |
||
Recognition speed |
<500ms |
||
Recognition distance |
0.4-2m |
||
Recognition Height |
1.2-2.2m, angle adjustable |
||
Vertical angle |
60° |
||
Horizontal angle |
40° |
||
Multiple recognition mode |
Face recognition, face recognition + temperature measurement, temperature measurement,Face recognition + mask detection + temperature detection and other recognition modes |
||
Face library |
Supports max. 50000 pcs of faces |
||
Comparison records |
Max.100000 records, export available |
||
Temperature measurement |
Temperature measurement environment |
10-35 (℃) (the best working temperature for body temperature measurement is 16~32℃), there is no wind in the room (see note for details) |
|
Accuracy |
±0.3℃ |
||
Range |
30-45(℃) |
||
Temperature measurement method |
Array |
||
Best distance |
40CM |
||
Response time |
<500ms |
||
Alarm |
Abnormal temperature alarm (threshold adjustable) |
||
Face + mask detection |
Accuracy |
≥85% |
|
Mask wearing alert |
Voice broadcast |
||
Voice broadcast |
Multiple mode |
Face recognition authentication result broadcast, temperature normal or abnormal result broadcast and mask wearing or not alert broadcast |
|
Hardware |
Image sensor |
Sensor type |
1/2.8" Progressive Scan CMOS |
Effective resolution |
2.0 mega-pixels, 1920*1080 |
||
Min. Lux |
Color 0.01Lux @F1.2(ICR); B/W 0.001Lux @F1.2 |
||
SNR |
≥50db(AGC OFF) |
||
WDR |
≥80db |
||
Lens |
Binocular camera: visible light lens + NIR lens |
||
Lens |
4.5mm |
||
Screen |
Size |
7 inch |
|
Resolution |
600*1024 |
||
Display scale |
16:9 |
||
Audio |
Speaker |
2* (8Ω 1W) |
|
Interfaces |
Network |
RJ45 10M/100M self-adaptive Ethernet port |
|
Wiegand port |
Wiegand input and output support, support standard 26bit/34bit format |
||
Alarm output |
1ch |
||
USB port |
1ch (connect the external ID identifier) |
||
Others |
Power supply |
DC12V±25% |
|
Power consumption |
20W(MAX) |
||
Protective grade |
IP34 |
||
Working temperature |
-20℃~60℃(Access control product);10℃~35℃ (Temperature module) |
||
Working humidity |
5~90%, no condensation |
||
Dimension |
123.5(W) *84(T) *361.3(H)mm |
||
N. weight |
1.4kg |
||
Stand diameter |
27mm |
NO. |
Name |
Mark |
Instruction |
J1 |
Wiegand output |
WG OUT |
Recognize the output result or connect other WG input devices |
J2 |
Wiegand input |
WG IN |
Unavailable |
J3 |
Alarm output |
ALARM OUT |
Switching alarm signal output |
J4 |
USB |
|
Connect the ID identifier or other USB devices |
J5 |
DC12V power supply |
DC12V |
DC12V±25%power supply |
J6 |
RJ45 |
|
10/100Mbps Ethernet port |
Notices
1. Temperature measurement device should be operated indoor during 10℃-35℃. Please do not install
it near the vent or the heat source
2. Staff from the outdoor cold environment will affect the temperature measurement accuracy, please
stay indoor for a while then continue measurement.
3. Device measured the forecast temperature, when forecast is wet or covered by other goods, the measured
Temperature will be lower than the actual one.
4. Start the test after 20 minutes of warm-up